DynamicRoll CB230 – Technical Data Sheet

BMP Europe / Technical Data Sheets

BMP DynamicRoll CB230 is a self-repairing industrial high-speed roll-up door designed to separate sterile and pressure-controlled environments, including areas maintained at positive air pressure.

Its sealing system helps limit uncontrolled air leakage between adjacent spaces, supporting ventilation and air purification systems. The door incorporates a counterweight system that allows emergency opening in the event of a power failure.

This page presents selected specifications from the DynamicRoll CB230 Lite technical data sheet, including performance, air permeability, control and safety equipment, curtain materials and accessories.

Product Overview

High-speed cleanroom door with counterweight emergency opening.

DynamicRoll CB230 uses a patented sliding system with high-density, self-lubricating Polyzene guides and a zipper integrated into the flexible PVC curtain. After an impact, the curtain can leave the side guides and reinsert during the following operating cycle. The curtain has no rigid horizontal reinforcement elements.

Technical Specifications

Published performance and construction data from the official Lite data sheet.

Maximum dimensions W 4,500 mm × H 4,500 mm
Maximum opening speed Up to 2.5 m/s
Closing speed 0.8 m/s
Cycle test 1,000,000 cycles
Air permeability Class 2; Class 5 with the optional patented magnetic sealing system
Structure Not self-supporting
Frame and motor cover hood Standard: galvanized steel. Optional: powder-coated steel or stainless steel 441/316
Standard curtain PVC curtain, 900 g/m²
Optional curtain types Insulated, translucent (35–40%), FDA white, antistatic
Sliding system Patented zipper-guided system with high-density, self-lubricating Polyzene
Wiring Plug-and-play system, IP65
Emergency opening Standard: counterweight system. Optional: UPS battery

Air Permeability and Cleanroom Applications

Controlled air leakage in pressurised environments.

The CB230 is designed for cleanroom and other pressure-controlled installations where separating areas while limiting air leakage is important. The optional magnetic sealing system provides a Class 5 air permeability configuration. The manufacturer also references testing at a pressure differential of 50 Pa.

  • Designed for sterile and overpressurised environments
  • Optional magnetic sealing system for low air permeability
  • Counterweight arrangement for emergency opening
  • Self-repairing flexible curtain without rigid horizontal elements

Air permeability classes describe the door's leakage performance and should not be confused with ISO 5 cleanroom classification. Verify the selected configuration and test documentation for the intended application.

Control System and Safety

Power supply, control electronics and safety devices.

Standard control box Powder-coated steel, IP54, 300 × 500 × 150 mm
Optional control boxes Stainless steel; PVC box IP65, 300 × 400 × 150 mm
Control electronics Inverter system 50/60 Hz with absolute encoder
Power supply options Single-phase 230 V, max 16 A; three-phase 400 V, max 10 A; three-phase 230 V, max 16 A
Control functions Start/Stop button; two free contacts for door open, door closed and alert; automatic/manual interlocking between two doors
Motor and control panel protection IP54
Standard safety devices Photocell set IP65, anti-jam reverse sensor, wireless safety edge IP65
Optional safety device Multi-ray light curtain H2500, IP67

Standard PVC Curtain Characteristics

Material composition and tests from the manufacturer's data sheet.

External material Opaque PVC, 0.7 mm; 18 standard colours
Internal material Rough PVC, 0.2 mm; 18 standard colours
Fabric PES, one fabric layer, 1100 Dtex, 12 × 12
Tested thickness 0.9 ± 0.1 mm, ISO 2286-3
Reported material weight 900 g/m²; 0.90 ± 0.1 kg/m², ISO 2286-2

FDA-Designated Curtain Material

PUR-coated white fabric described in the Lite data sheet.

Coating White polyurethane (PUR) on both sides
Coating thickness 0.6 mm on each side
Fabric PET, one fabric layer, 2200 Dtex, 12 × 12
Tested thickness 1.20 ± 0.1 mm, ISO 2286-3
Tensile strength, warp 6,000 N / 50 mm, ISO 1421

The FDA-designated material table reports 1,500 g/m² in one weight entry and 1.30 ± 0.1 kg/m² in another. Confirm the applicable weight and regulatory documentation before selecting this material.

Transparent Window Characteristics

Superclear PVC window specifications.

Material PVC Superclear 0.75 mm FR
Thickness 0.75 mm
Total PVC weight 940 g/m²
Light transmission 87.5%, JIS K 7361
Temperature limitation Suitable only for positive-temperature environments

The positive-temperature limitation refers specifically to the Superclear window material described above. The original PDF contains a separate, ambiguous statement about the door's operating temperature that should be clarified with BMP Europe.

Optional Accessories

Sensors, opening devices and traffic control equipment.

  • TOF/Spot opening point radar for internal use
  • Infrared radars for cross-movement, motion and presence detection
  • Fixed red and green traffic lights, LED countdown signals and barriers
  • Opening buttons, freeze-stop and no-touch controls
  • Dual-function traffic-light button for opening and closing indications
  • Wind gauge, key selector, remote control and B-Protect bollard
  • Pull-cord switch and magnetic loop detector

Technical Documentation

Access the public DynamicRoll CB230 Lite technical data sheet or request the complete product documentation.

Public Documentation

The Lite PDF includes published performance, sealing characteristics, control and safety equipment, curtain materials and optional accessories.

Download Lite Technical Data Sheet (PDF)

Need More Detailed Technical Information?

The complete BMP DynamicRoll CB230 technical data sheet is available through the official product download request form. Complete the form to access the full documentation.

Request Complete Technical Data Sheet