BMP DynamicRoll DynaDry – Installation, Use and Maintenance Manual

This page provides technical information for the BMP Europe DynamicRoll DynaDry industrial high-speed door, based on the official Installation, Use and Maintenance Manual, Revision 9.

The documentation covers DynaDry-specific mechanical assembly, anti-drip profile installation, curtain slide positioning, electrical wiring, BMP2 control board functions, alarm codes, operating modes, interlock and periodic maintenance.

Document Information

Manufacturer: BMP EUROPE Srl
Product: DynamicRoll DynaDry
Official document: Installation, Use and Maintenance Manual
Revision: Rev. 9
Cover version: V.26/4
Language: English
Document length: 28 PDF pages
Control board described: BMP2 V04/V05/V06

The official document covers DynamicRoll, DynamicRoll Food Inox, DynamicRoll 90 and DynamicRoll DynaDry. This page focuses on the DynaDry model and identifies its dedicated installation instructions.

DynamicRoll DynaDry Installation Overview

The DynamicRoll DynaDry installation includes model-specific components and procedures in addition to the common DynamicRoll assembly steps.

In particular, the manual illustrates the installation of the metal anti-drip profile and curtain slides in the DynaDry configuration.

Before installation, the opening dimensions, supporting structure and possible obstructions must be checked. Structural fixing requirements are documented on page 4.

DynaDry Mechanical Assembly

Page 6 contains the dedicated installation drawings for DynamicRoll DynaDry.

The illustrated assembly covers fastening the side columns to the top heading, checking alignment and completing the structural fixings.

For doors larger than 4 × 4 m, the manual describes temporarily securing the columns to the structure before lifting and attaching the top heading.

The installation drawings specify a diagonal alignment tolerance of B = C ± 5 mm. For a door width greater than 4 m, the top heading must be supported at intervals of at least 2 m.

The drawings and fixing details are provided on page 6 of the official manual.

Metal Anti-Drip Profile Installation

Page 7 provides a dedicated installation sequence for the DynaDry metal anti-drip profile.

The sequence illustrates how to identify the prepared fixing points, position and rotate the profile between the guides, and secure the component.

The original drawings show the component orientation and fixing arrangement. Follow these illustrations during installation.

Curtain Slide Installation and Adjustment

Pages 8-9 document the installation and positioning of the DynaDry curtain slides.

The manual illustrates configurations with different numbers of curtain slide elements, depending on the door width and installation.

PDF page Illustrated configuration
8 1 curtain slide element
8 2 curtain slide elements
8 3 curtain slide elements
8 4 curtain slide elements
9 Curtain slide positioning, horizontal adjustment and fastening

Page 9 identifies the horizontal adjustment screws and illustrates the positioning of each element in relation to the anti-drip profile.

Use the original dimensional drawings to determine the correct arrangement for the installed door.

Curtain Tension and Safety Light Curtain

Page 10 describes curtain tension adjustments and safety light curtain positioning.

The manual also includes a precaution for the optional front motor configuration, requiring verification of the transmission chain tension.

Safety light curtain positioning and fixing details are illustrated in the original PDF.

Electrical Wiring Diagrams and Spider Connections

Pages 11-15 contain electrical connections for the encoder, safety devices, accessories and BMP2 control board.

PDF page Technical documentation
11 Absolute encoder, infrared photocells, Spider Cable distributor and associated wiring
12 Absolute encoder and safety light curtain connections
13 Accessory connections: radar, laser, traffic lights, push buttons, magnetic loop, radio controls and other devices
14 BMP2 power connections, DIP switches and LED indicators
15 Control board input terminals, safety devices and encoder software verification

Spider Cable Wiring

Page 11 contains the original Spider Cable wiring diagram for the encoder and infrared photocell configuration.

The drawing identifies the control panel, three-phase motor, electro-brake, Spider signal distributor, encoder, curtain top sensor, photocell receiver and transmitter, and wireless safety edge transmitter.

Cable cross-sections and connector identification are documented in the original diagram.

Electrical connections must match the installed equipment and be carried out by qualified personnel. The official wiring diagrams remain the reference.

BMP2 Control Board Specifications

Pages 14-16 document the BMP2 control board used in the configurations described by this manual.

Characteristic Documented information
Control board versions BMP2 V04/V05/V06
Power supply 208-460 V AC ±10%, 50/60 Hz, three-phase
Motor reference 2.2 kW, 50-80 Hz
Position detection Absolute encoder
FIX_03 encoder firmware Version 1_7 or later
Inverter software Version 02.21.3805 or later

The electrical configuration must match the identification data of the actual equipment.

On-Board Controls

Button Function
P1 Jog Open command and menu navigation
P2 Teaching and menu selection
P3 Jog Close command and menu navigation

The original control board diagrams and terminal assignments are on pages 14-15.

Operating Options and Advanced Functions

Page 16 provides the running options available for the control board.

Documented functions include:

  • UPS activation
  • START input closing behaviour
  • Automatic closing after transit
  • Encoder time monitoring
  • Automatic deicing
  • Wi-Fi interlock
  • Automatic interlock
  • Manual interlock
  • Automatic START after power interruption
  • Radar input options
  • Alarm relay functions
  • Extra opening limit

Some functions require an LCD programmer or additional accessories. Refer to the original manual for the permitted configurations.

Alarm Codes and Fault Diagnosis

Pages 17-18 provide the alarm reference tables for the BMP2 control board.

The board reports alarms with the prefix AL followed by a four-character code.

Alarm code Description
0004 / 0005 Electronic control board failure
0011 STOP error sequence
0012 Motor short circuit
0013 a-e Absolute encoder position error
0032 Overload
0050 Brake interrupted
0051 Brake overload
0052 Position below ground level
0053 Position beyond the opening limit
0055 Incompatible UPS version
0056 / 0070 Invalid learning procedure
0074 Anti-jamming activation
0076 Power supply fault
0079 Safety edge activation
007A UPS power supply fault
0080-0086 Software error codes
0087 Overvoltage
008D Overtemperature
008F Ignition voltage fault
0091 / 0093 / 0094 / 0095 / 0097 Software error
0103 Photocell blocked during teaching
010E Door stalled
0116 / 0117 / 0118 Motor configuration error
0136 Encoder data communication error
0138 Encoder battery fault
013A Lost encoder position

The original alarm tables include diagnostic checks and corrective actions. These must be performed by qualified personnel.

Verify the installed control board version and software before using the alarm references.

Display Status Codes

Page 19 lists the operating status indications shown on the BMP2 control board display.

Code Meaning
CDoor closed
ODoor opened
OPDoor opening
CLDoor closing
PEPedestrian operation
StSTOP activated
JJog operation
tADoor measurement teaching
tPPedestrian teaching
-.-Teaching required
SEService expired
SnService approaching
UPSUPS opening
UPS-Opened UPS mode
UPSFUPS fault
UPSCUPS closing
UPSOUPS obstacle
ALnnnnAlarm code

Display Functions with STOP Pressed

Page 20 documents the parameters available through the control board interface with STOP active.

Parameter Function
to Automatic pause time
nO Minimum motor torque during opening
nC Minimum motor torque during closing
So Opening speed
Sc Closing speed
OP Open position adjustment
O2 Intermediate opening position
CL Close position adjustment
Fo Photocell exclusion point
r1-r6 Relay contact functions
Fu Automatic closing, UPS and interlock options

Page 21 describes the available relay function cases, including open and close status, pedestrian opening, interlock, flashing signals and alarm contacts.

Automatic, Manual and Wi-Fi Interlock

Page 22 describes the interlock system for coordinating two or more doors.

The documented functions include:

  • Wired automatic interlock
  • Wired manual interlock
  • Wi-Fi interlock with LCD programmer

The system prevents a second door from opening while another interlocked door is open or opening.

The Wi-Fi interlock configuration requires the LCD programmer to remain connected.

Refer to page 22 for the wiring diagram and programming references.

Manual Operation and Power Failure

Page 23 describes manual operation during a power failure or breakdown.

The procedure uses the manual motor coupling after the main power supply has been isolated.

The manufacturer states a sound pressure level below 70 dB(A).

Follow the original safety instructions before operating the manual mechanism.

Periodic Maintenance and Safety Checks

Pages 23-24 describe maintenance requirements for users and trained operators.

The manual specifies six-month intervals for the listed routine checks:

  • Visual inspection of main door components
  • General cleaning of the installation
  • Cleaning of photocells and signalling devices
  • Verification of safety device operation
  • Inspection of accessible junction and movement points
  • Verification of structural fixings

The checklist also includes inspection of bearing support fixings, mechanical couplings and horizontal movement of the tube.

Maintenance work beyond the permitted routine checks must be carried out by technicians authorised by the manufacturer.

Annex A contains the maintenance record.

Official PDF Manual

Download the complete official BMP DynamicRoll DynaDry Installation, Use and Maintenance Manual, including DynaDry-specific assembly drawings, anti-drip profile installation, curtain slide positioning, electrical wiring diagrams, BMP2 control board instructions, alarm tables and maintenance records.

Download Official DynamicRoll DynaDry Manual (PDF)

BMP Europe Official Documentation | English | Revision 9 | 28 pages

Technical Documentation Notice

This page provides a structured technical reference to the official BMP Europe DynamicRoll DynaDry manual.

The document also includes information for DynamicRoll, DynamicRoll Food Inox and DynamicRoll 90.

The original PDF remains the reference for model-specific installation drawings, electrical connections, programming and safety procedures.

Always verify the installed equipment and control board configuration before applying technical instructions.