DynamicRoll DynaDry – Technical Data Sheet

BMP Europe / Technical Data Sheets

BMP DynamicRoll DynaDry is a self-repairing industrial high-speed door featuring a patented anti-drip system designed to collect and discharge water produced by condensation.

The system helps prevent water from falling into the passageway when the door opens, protecting products, equipment and people moving beneath the opening. The door is designed to be washable and suitable for industrial applications with demanding hygiene requirements.

This page presents the public DynamicRoll DynaDry Lite technical specifications, including door performance, curtain materials, safety systems and accessories. The complete technical data sheet is available through the official request form.

Product Overview

Self-repairing industrial door with a patented anti-drip system.

DynamicRoll DynaDry combines a flexible PVC curtain with a water collection and drainage system integrated into the upper door assembly. It is intended for environments where condensation can form on the curtain and create a risk of dripping during opening. The door's construction also facilitates cleaning and washing.

Patented Anti-Drip and Water Discharge System

Condensation management and protection of the passageway.

The patented anti-drip arrangement is designed to collect water from condensation on the door curtain and guide it towards the sides of the opening instead of allowing it to fall onto goods or personnel. This feature is particularly useful where differences in temperature and humidity can cause moisture to accumulate on door surfaces.

  • Helps prevent condensation from dripping into the passageway
  • Directs collected water away from the central opening
  • Protects goods passing beneath the open door
  • Washable door design for hygiene-sensitive applications

Technical Specifications

Published data from the official Lite technical sheet.

Maximum dimensions W 6,500 mm × H 6,500 mm
Maximum opening speed Up to 2.5 m/s
Cycle test 1,000,000 cycles
Air permeability Class 3 at 3,000 × 3,000 mm; Class 2 at 5,000 × 5,000 mm, as reported in the Lite sheet
Structure Not self-supporting
Frame and motor cover hood Galvanized steel and stainless steel 441/304, as listed in the technical table
Standard curtain PVC curtain, 900 g/m²
Optional curtain types Translucent (35–40%), FDA white and antistatic
Sliding system Patented zipper-guided sliding system with high-density, self-lubricating Polyzene
Wiring Plug-and-play system, IP65

The air permeability classifications above are reproduced from the manufacturer's Lite sheet. Their applicability should be verified for the selected dimensions and configuration.

Control System and Safety

Control panel equipment, safety devices and emergency opening.

Standard control panel PVC enclosure, 300 × 400 × 150 mm
Optional control panels Stainless steel or powder-coated steel IP54, 300 × 500 × 150 mm
Inverter and encoder 50/60 Hz inverter system with absolute encoder
Power supply options Single-phase 230 V, max 16 A; three-phase 400 V, max 10 A; three-phase 230 V, max 16 A
Control functions Start/Stop button; two free contacts for door open, closed and alarm; automatic/manual interlocking between two doors
Motor and control panel protection IP54
Standard safety devices IP65 photocells and anti-jam reverse sensor
Optional safety devices Wireless safety edge IP65 and multi-ray light curtain H2500 IP67
Emergency opening Standard: hand crank. Optional: chain system or UPS battery

Standard PVC Curtain Characteristics

Composition and material test values from the Lite sheet.

External PVC Opaque finish, 0.7 mm; 18 standard colours
Internal PVC Rough finish, 0.2 mm; 18 standard colours
Fabric PES, one layer, 1100 Dtex, 12 × 12
Tested thickness 0.9 ± 0.1 mm, ISO 2286-3
Weight 900 g/m²; 0.90 ± 0.1 kg/m², ISO 2286-2
Cold resistance test -50°C ± 5°C, ISO 4675/90
Storage temperature -30°C to +65°C
Fire classification S-b2 D0, as printed in the source document, reference EN 13501-1:2018
Tensile strength / load break 6,000 N / 50 mm, ISO 1421

Material resistance and storage test temperatures do not establish the operating temperature range of the complete door. The Lite sheet contains an ambiguous operating-temperature statement that should be clarified with BMP Europe before use.

Insulated PVC Material Characteristics

Additional insulated PVC material described in the public PDF.

External PVC Straight finish, 0.5 mm; six standard colours
Internal PVC Sponge finish, 7 mm
Fabric PES, one layer, 1100 Dtex, 12 × 12
Tested thickness 7.0 ± 0.1 mm, ISO 2286-3
Reported weight values 1,350 g/m² and 1.7 ± 0.1 kg/m², as listed in the source
Cold resistance test -10°C ± 5°C, ISO 4675/90
Storage temperature -30°C to +65°C
Sound insulation index Rw = 17.5 dB

The two weight values shown in the insulated PVC section are not numerically equivalent. Their respective meanings should be confirmed with the manufacturer. Availability of insulated PVC for the selected DynaDry configuration must also be verified.

Transparent Window Characteristics

PVC Superclear specifications from the Lite data sheet.

Material PVC Superclear 0.75 mm FR
Thickness 0.75 mm
PVC weight 940 g/m²
Light transmission 87.5%, JIS K 7361
Tear strength Lengthwise: 55.6 N; crosswise: 57.4 N, JIS K 6732
Cold crack resistance test -40°C, JIS K 6772
Temperature limitation Suitable only for positive-temperature environments
Flame retardancy No, as stated in the Superclear material table

The positive-temperature restriction refers to the Superclear transparent PVC material. A cold-crack test result must not be interpreted as permission to operate this window material at sub-zero temperatures.

FDA-Designated Curtain Material

PUR-coated fabric specifications contained in the public PDF.

Coating material White polyurethane (PUR) on both sides
Coating thickness 0.6 mm per side
Fabric PET, one layer, 2200 Dtex, 12 × 12
Tested thickness 1.20 ± 0.1 mm, ISO 2286-3
Tensile strength, warp 6,000 N / 50 mm, ISO 1421
Reported material weights 1,500 g/m² and 1.30 ± 0.1 kg/m²

The manufacturer's FDA material section reports different weight values. Confirm the applicable material specification and relevant compliance documentation before selecting this option.

Optional Accessories

Sensors, opening controls and traffic signalling equipment.

  • TOF/Spot opening point radar for internal use
  • Infrared radars for cross-movement, motion and presence detection
  • Fixed red and green traffic lights, LED countdown lights and barriers
  • Green and black opening buttons, freeze-stop and no-touch controls
  • Dual-function traffic-light button for opening and closing signalling
  • Wind gauge, key selector, remote control and B-Protect bollard
  • Pull-cord switch and magnetic loop detector

Technical Documentation

Access the public DynamicRoll DynaDry Lite technical data sheet or request the complete product documentation.

Public Documentation

The Lite PDF includes product specifications, the anti-drip system, safety equipment, material properties and optional accessories.

Download Lite Technical Data Sheet (PDF)

Need More Detailed Technical Information?

The complete BMP DynamicRoll DynaDry technical data sheet is available through the official product download request form. Complete the form to access the full documentation.

Request Complete Technical Data Sheet