BMP DynamicRoll – Installation, Use and Maintenance Manual

This is the official installation, use and maintenance manual for BMP Europe Dynamicroll high-speed doors, Revision 9.

The document provides instructions and technical references for installation, electrical connections, control board operation, alarm diagnosis, manual operation and periodic maintenance.

Document Information

Manufacturer: BMP EUROPE Srl
BMP EUROPE Srl
Document: Installation, Use and Maintenance Manual
Language: English
Document revision: Rev. 9
Cover version: V. 25/7
Length: 24 PDF pages

Applicable Models

According to the official document, this manual applies to the following BMP high-speed doors:

  • Dynamicroll
  • Dynamicroll Food Inox
  • Dynamicroll 90
  • Dynamicroll Low Headroom

Model-specific installation instructions are included in the document. Refer to pages 5 and 6 for the corresponding fixing arrangements.

Installation and Mechanical Assembly

Pages 4–7 describe installation requirements, doorway measurements, support structures, fixing arrangements, curtain tension and safety light curtain installation.

Before installation, the manual requires checking the dimensions of the opening and the suitability of the supporting structure.

Model-specific fixing diagrams are provided on pages 5 and 6.

DynamicRoll Installation Video

Watch the BMP Europe DynamicRoll installation video for a visual guide to the assembly and mounting procedures.

For complete installation instructions, technical specifications and safety requirements, always refer to the official installation manual.

Watch the DynamicRoll Installation Video on YouTube

Electrical Connections and Wiring

Pages 8–10 contain the electrical connection diagrams and cable references for the door components and accessories.

Documented Connections

  • Encoder and photocells using the Spider cable connection system (page 8).
  • Encoder and safety light curtain connections (page 9).
  • Electrical connections for opening devices, signalling devices and accessories (page 10).

The original diagrams identify the relevant components, terminals, wiring arrangements and cable specifications.

Electrical work must be carried out using the diagrams applicable to the installed equipment and its configuration.

Control Board and Operating Functions

Pages 11–13 describe the electronic control board, electrical power connections, DIP switch functions, indicator LEDs, on-board controls and operating options.

The control board connection section specifically references BMP2 V04/05/06.

The manual also describes the functions of the P1, P2 and P3 on-board keys and the available operating options.

Control board revision and software compatibility must be verified before applying configuration instructions.

Alarm Codes and Fault Diagnosis

Pages 14–15 contain the control board alarm reference tables, including alarm descriptions and corresponding troubleshooting information.

When the control board detects certain faults or incorrect system connections, the display shows the prefix AL followed by a four-digit alarm code.

The documented alarm categories include electronic control board faults, motor conditions, encoder errors, safety devices, power supply faults and software errors.

Always consult the complete alarm tables in the official PDF before carrying out corrective operations.

Display Status and Parameter Settings

Page 16 lists the display status indicators, including door operating states, UPS conditions, alarm notifications and maintenance reminders.

Pages 17–18 describe the available parameter adjustment functions and relay contact configurations.

Interlock Functions

Page 19 describes the interlock system used to coordinate the operation of two or more doors.

The manual includes automatic interlock, manual interlock and Wi-Fi interlock configurations, together with the relevant connection and programming references.

Manual Operation

Page 20 describes manual operation of the door curtain in the event of power failure or breakdown.

Follow the original procedure and all applicable safety precautions before operating the equipment manually.

Periodic Maintenance and Safety Checks

Pages 20–21 describe periodic maintenance requirements and safety precautions for users and trained operators.

The maintenance schedule specifies six-month intervals for checks involving:

  • General condition of the main door components.
  • Cleaning of the door system.
  • Cleaning of installed safety and signalling devices.
  • Functional verification of safety devices.
  • Accessible junction and movement points.
  • Structural fixing and stability.

The manual specifies that checks and interventions beyond those described must be carried out by technicians authorised by the manufacturer.

Annex A on page 22 contains the maintenance record.

Official PDF Manual

Download the complete BMP DynamicRoll installation, use and maintenance manual, including electrical wiring diagrams, control board information, alarm tables, safety requirements and maintenance procedures.

Download DynamicRoll Manual (PDF)

BMP Europe Official Documentation | English | 24 pages

Technical Documentation Notice

This page provides a structured reference to the official BMP Europe technical manual. It does not replace the complete document.

Technical instructions must be checked against the installed door model, control board version and applicable equipment configuration.

Installation, electrical work and maintenance must follow the manufacturer's instructions and applicable safety requirements.